600Volt. CopperConductor
XLPE InsulationMoisture /Heat /Low-Temp /Sunlight Resistant Flame Retardant
Thermoset Insulated Wire and Cable
APPLICATIONS
XHHW-2building wire is intended for general purpose applications utilized in conduit and tubing underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the USA National Electrical Code (NEC). XHHW-2CU is permitted for 600-volt applications and can be used in wet or dry locations at temperatures not to exceed 90˚C. It’s suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less.With the specialinsulation, the wire requires no lubrication for installation.
STANDARDS
Morn’s XHHW-2complies with the following:
•ASTMB3, B8
•USA National Electrical Code, NFPA 70, 2014Edition
•Solid soft-annealeduncoated copper (14-8 AWG) |
|
|
• Strandedcompressed/compacted soft-annealeduncoated copper (6 AWG-2000 kcmil) |
Insulation |
•Cross-linked polyethylene (XLPE) insulation, abrasion /moisture /heat /low-temp /sunlight resistant, flame retardant |
TECHNICALPARAMETERLIST
Size (AWG or kcmil) |
Number of Strands |
Insulation Thickness (mils) |
Nominal O.D. (mils) |
Approx. Weight per 1000' (lbs) |
Allowable Ampacities |
||
60°C |
75°C |
90°C |
|||||
14 |
1 |
30 |
124 |
16 |
15 |
20 |
25 |
12 |
1 |
30 |
141 |
24 |
20 |
25 |
30 |
10 |
1 |
30 |
162 |
37 |
30 |
35 |
40 |
8 |
1 |
45 |
218 |
60 |
40 |
50 |
55 |
6 |
7 |
45 |
268 |
92 |
55 |
60 |
65 |
4 |
7 |
45 |
315 |
142 |
70 |
85 |
95 |
3 |
7 |
45 |
342 |
177 |
85 |
100 |
115 |
2 |
7 |
45 |
373 |
220 |
95 |
115 |
130 |
1 |
19 |
55 |
432 |
280 |
100 |
130 |
145 |
1/0 |
19 |
55 |
472 |
349 |
125 |
150 |
170 |
2/0 |
19 |
55 |
516 |
436 |
145 |
175 |
195 |
3/0 |
19 |
55 |
567 |
544 |
165 |
200 |
225 |
4/0 |
19 |
55 |
622 |
681 |
195 |
230 |
260 |
250 |
19 |
65 |
689 |
811 |
215 |
255 |
290 |
300 |
37 |
65 |
740 |
965 |
240 |
285 |
320 |
350 |
37 |
65 |
791 |
1118 |
260 |
310 |
350 |
400 |
37 |
65 |
835 |
1277 |
280 |
335 |
380 |
500 |
37 |
65 |
917 |
1583 |
320 |
380 |
430 |
600 |
61 |
80 |
1026 |
1914 |
350 |
420 |
475 |
700 |
61 |
80 |
1093 |
2225 |
385 |
460 |
520 |
750 |
61 |
80 |
1128 |
2378 |
400 |
475 |
535 |
1000 |
61 |
80 |
1278 |
3153 |
455 |
545 |
615 |
NOTE: Other conductor sizes are available upon request.