600 Volt. Copper Conductors, XHHW-2as Inners, Single Green Insulated/Bare Grounding Conductor, Aluminum Alloy Interlocked Armor, PVC Jacket Low-Temp, Oil, Sunlight Resistant, Flame Retardant, Direct Burial Metal Clad Cable
APPLICATIONS
Morn Type MC cable complies with the following:
•Permitted use for service, feeders and branch circuits in residential, commercial, industrial, and multi-residential buildings;
•Acceptable for power, lighting, control, and signal circuits;
•Utilized for indoor or outdoor applications, and allowable for concealed or exposed systems;
•Permitted in wet locations per USA NEC 330.10(A)(11)(a);
•Permitted for direct burial in the earth or embedded in concrete per USA NEC 330.12(2)(a);
•Allowable in assembly occupancies (USA NEC 518.4);
•Permissible in theaters, audience areas of motion pictures, television studios, and similar locations (USA NEC 520.5);
• Permitted as aerial cable on a messenger (USA NEC 396.10(A));
•Suitable for installation under raised floors for IT equipment (USA NEC 645.5) ;
•Allowable installations in approved raceways and cable trays (USA NEC 392);
•Permitted in Class I Div. 2, Class II Div. 2, and III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3Hour Through-Penetration Firestop Systems;
STANDARDS
Morn’sType MC Cable complies with the following:
• UL 44
• UL 1569
CONSTRUCTION
•Solid soft-annealed uncoated copper (14-10 AWG) ••Compact/compressed Stranded uncoated copper (8 AWG -1000 kcmil) |
|
Insulation |
•Cross-linked polyethylene (XLPE) 90°C rated |
Grounding |
•Green insulated copper grounding conductor (Phase conductor : 14-1 AWG) •Bare copper grounding conductor (Phase conductor : 1/0 AWG -1000 kcmil) |
Assembly |
•Separator tape |
Armor |
•Aluminum Alloy Interlocked Armor (AIA) |
Jacket |
••Polyvinyl Chloride (PVC) jacket 90°C rated, Black, Low-Temp, Oil, Sunlight Resistant, Flame Retardant |
TECHNICAL PARAMETER LIST
ConductorSize(AWGor kcmil) -Conductor No. |
Number of Strands |
Grounding Conductor Size (AWG)/Type |
Outside Diameter Over Armor(mils) |
Jacket Thickness (mils) |
Overall Diameter (mils) |
Weight (Lbs./ 1000 Ft.) |
Allowable Ampacity |
|
75°C |
90°C |
|||||||
1 |
14/Green insulated |
453 |
50 |
553 |
145 |
20 |
25 |
|
14-3 |
1 |
14/Green insulated |
483 |
50 |
583 |
167 |
20 |
25 |
14-4 |
1 |
14/Green insulated |
517 |
50 |
617 |
192 |
20 |
25 |
12-2 |
1 |
12/Green insulated |
531 |
50 |
631 |
175 |
25 |
30 |
12-3 |
1 |
12/Green insulated |
543 |
50 |
643 |
201 |
25 |
30 |
12-4 |
1 |
12/Green insulated |
562 |
50 |
662 |
240 |
25 |
30 |
10-2 |
1 |
10/Green insulated |
534 |
50 |
634 |
223 |
35 |
40 |
10-3 |
1 |
10/Green insulated |
575 |
50 |
675 |
269 |
35 |
40 |
10-4 |
1 |
10/Green insulated |
621 |
50 |
721 |
315 |
35 |
40 |
8-2 |
7 |
10/Green insulated |
677 |
50 |
777 |
314 |
50 |
55 |
8-3 |
7 |
10/Green insulated |
757 |
50 |
857 |
395 |
50 |
55 |
8-4 |
7 |
10/Green insulated |
834 |
50 |
934 |
474 |
50 |
55 |
6-2 |
7 |
8/Green insulated |
791 |
50 |
891 |
430 |
65 |
75 |
6-3 |
7 |
8/Green insulated |
884 |
50 |
984 |
542 |
65 |
75 |
6-4 |
7 |
8/Green insulated |
974 |
50 |
1074 |
657 |
65 |
75 |
4-3 |
7 |
8/Green insulated |
964 |
50 |
1064 |
719 |
85 |
95 |
4-4 |
7 |
8/Green insulated |
1070 |
50 |
1170 |
888 |
85 |
95 |
3-3 |
7 |
6/Green insulated |
1049 |
50 |
1149 |
874 |
100 |
115 |
3-4 |
7 |
6/Green insulated |
1164 |
50 |
1264 |
1079 |
100 |
115 |
2-3 |
7 |
6/Green insulated |
1103 |
50 |
1203 |
1025 |
115 |
130 |
2-4 |
7 |
6/Green insulated |
1228 |
50 |
1328 |
1277 |
115 |
130 |
1-3 |
19 |
6/Green insulated |
1195 |
50 |
1295 |
1162 |
130 |
145 |
1-4 |
19 |
6/Green insulated |
1336 |
50 |
1436 |
1477 |
130 |
145 |
1/0-3 |
19 |
6/Bare |
1213 |
50 |
1313 |
1359 |
150 |
170 |
1/0-4 |
19 |
6/Bare |
1335 |
50 |
1435 |
1742 |
150 |
170 |
2/0-3 |
19 |
6/Bare |
1308 |
50 |
1408 |
1624 |
175 |
195 |
2/0-4 |
19 |
6/Bare |
1441 |
50 |
1541 |
2092 |
175 |
195 |
3/0-3 |
19 |
4/Bare |
1415 |
50 |
1515 |
2048 |
200 |
225 |
3/0-4 |
19 |
4/Bare |
1562 |
60 |
1682 |
2637 |
200 |
225 |
4/0-3 |
19 |
4/Bare |
1536 |
60 |
1656 |
2498 |
230 |
260 |
4/0-4 |
19 |
4/Bare |
1696 |
60 |
1816 |
3233 |
230 |
260 |
250-3 |
19 |
4/Bare |
1648 |
60 |
1768 |
2904 |
255 |
290 |
250-4 |
19 |
4/Bare |
1822 |
60 |
1942 |
3770 |
255 |
290 |
300-3 |
37 |
3/Bare |
1760 |
60 |
1880 |
3192 |
285 |
320 |
300-4 |
37 |
3/Bare |
1962 |
60 |
2082 |
4211 |
285 |
320 |
350-3 |
37 |
3/Bare |
1863 |
60 |
1983 |
3931 |
310 |
350 |
350-4 |
37 |
3/Bare |
2061 |
60 |
2181 |
5120 |
310 |
350 |
400-3 |
37 |
3/Bare |
1956 |
60 |
2076 |
4611 |
335 |
380 |
400-4 |
37 |
3/Bare |
2167 |
60 |
2287 |
5514 |
335 |
380 |
500-3 |
37 |
2/Bare |
2131 |
60 |
2251 |
5451 |
380 |
430 |
500-4 |
37 |
2/Bare |
2363 |
75 |
2513 |
7124 |
380 |
430 |
600-3 |
61 |
2/Bare |
2411 |
75 |
2561 |
6454 |
420 |
475 |
600-4 |
61 |
2/Bare |
2477 |
75 |
2627 |
8450 |
420 |
475 |
750-3 |
61 |
2631 |
75 |
2781 |
8015 |
475 |
535 |
|
750-4 |
61 |
1/Bare |
2923 |
75 |
3073 |
10506 |
475 |
535 |
NOTE: Other conductor sizes are available upon request.